Animal intensive care unit also can be called animal intensive medical care unit.
An intensive care unit in a separate cabin, which is suitable for smaller dogs, and cats to receive excellent treatment in the cabin. Animal intensive care unit is comfortable to operate such large screen human-computer interaction system. Through compressor refrigeration and PTC heating, the temperature is controlled by air circulation mode, making the temperature in the cabin balanced and comfortable. At the same time, Animal intensive care unit is significant that the efficient dehumidification function creates a better medical environment. In addition, it is very effective for the treatment of respiratory diseases when it starts with a higher concentration of oxygen since it has a fast interface of atomization therapy instrument. Moreover, it adds to a set of independent control module for disinfection and sterilization of cabin, which has great effects for the purification of the environment.
Product parameters | |||
Product Model |
LEILONG XS |
Display |
10-inch super large touch screen |
Input voltage |
AC100V/220V~ |
Sterilization system |
External 24 hours non-stop disinfection and sterilization deodorant system |
Frequency |
50/60 Hz |
Maximum power consumption |
1.3KW |
Temperature control mode |
4 chamber independent split cooling /PTC heating. |
Average power consumption |
0.5KW(Rooms 3-4 are used independently) |
Weight |
50 kg |
Power failure security |
Emergency ventilation hatch with programmed control |
Appearance size |
90CM×67CM×82CM |
Negative ion purification function |
(7.2X106PCS/cm3X4)High concentration anion |
Air purification function |
Ultraviolet germicidal lamp; |
Dehumidification indicators |
Automatic dehumidification system, standard humidity control at 40%, actual humidity control at < 50% |
Conditions of use |
-10℃~40℃Environment (indoor) |
Standard spare parts |
Various hanging racks and animal sleeping baskets (optional) |
Set temperature |
15-38℃The temperature control accuracy±0.5℃ |
Ultraviolet sterilization |
UVC band 253nm, efficient ultraviolet sterilization system |
Set oxygen concentration |
21℃-60℃Control precision±1% |
The fan control |
Automatic equalizing air supply |
Carbon dioxide concentration, monitoring and removal |
300-5000PPM,error±10PPM |
External humidifier |
Maximum atomization rate ≥ 0.2mL /min, fog particle (0.5-2um) noise ≤40dB(A)(optional) |
Alarm, warning |
Abnormal O2 concentration, temperature, sensor, CO2 concentration, and emergency hatch switch |
LED light |
There are two ways of light control: warm light is divided into ten levels and its strength can be adjusted, and cold light is used for medical examination |